Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 56
Filtrar
1.
Diabetes Technol Ther ; 26(3): 198-202, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38444312

RESUMO

The presence of diabetic ketoacidosis (DKA) at diagnosis of type 1 diabetes (T1D) is associated with higher glycated hemoglobin levels over time. We evaluated whether hybrid-closed loop (HCL) therapy from onset of T1D could prevent the adverse impact of DKA at diagnosis on long-term glycemic outcomes. This was a posthoc analysis from 51 adolescents using HCL from diagnosis of T1D as part of the CLOuD trial (NCT02871089). We compared glycemic and insulin metrics between adolescents with (n = 17) and without (n = 34) DKA at diagnosis. Participants with and without DKA at diagnosis had similar time in target glucose range 3.9-10.0 mmol/L (70-180 mg/dL), time below range (<3.9 mmol/L, <70 mg/dL) and HbA1c at 6, 12, and 24 months. While insulin requirements at 6 months were higher in those with DKA at diagnosis, this was not statistically significant after adjusting for bodyweight. Residual C-peptide secretion was similar between groups. We conclude that HCL therapy may mitigate against the negative glycemic effects of DKA at T1D diagnosis.


Assuntos
Diabetes Mellitus Tipo 1 , Cetoacidose Diabética , Adolescente , Humanos , Insulina/uso terapêutico , Diabetes Mellitus Tipo 1/complicações , Diabetes Mellitus Tipo 1/tratamento farmacológico , Cetoacidose Diabética/etiologia , Glicemia , Sistemas de Infusão de Insulina , Insulina Regular Humana
2.
Horm Res Paediatr ; 2024 Mar 12.
Artigo em Inglês | MEDLINE | ID: mdl-38471495

RESUMO

INTRODUCTION: Quantifying differences in service provision for children and young people (CYP) living with Congenital Adrenal Hyperplasia (CAH) across the United Kingdom. METHODS: A national service evaluation using online questionnaires circulated to patients and clinicians from secondary and tertiary UK centres managing CYP with CAH, and via the "Living with CAH" support group mailing list. RESULTS: Total of 195 responses relating to patients aged 0-20 years attending 33 clinics (43 patients, 152 carers), as well as 34 clinicians from 18 trusts working across the 33 clinics. Only 12% of clinicians were 'completely satisfied' with the service provided, compared to 68% of carers and 76% of patients. Whilst 94% of clinicians reported providing formal training to families with CAH, over 80% of both patients and carers reported not attending what they considered formal training. Appetite for further training was higher in carers (86%) than patients (55%), although further 'unsure' responses suggested formal training sessions would likely be well attended. Access to psychological services was difficult for 44% of clinicians. Biochemical monitoring of treatment was broadly in keeping with international guidelines, with 67% of clinicians reporting regular use of dried blood spots, and 12% regular urinary steroid metabolites. CONCLUSION: While there is overall good satisfaction with care provision among patients and carers with CAH in the UK, extra resources addressing the psychological and educational needs about the disease and its management would benefit patients and carers. Improved access to allied health professionals and psychologists will help support families and improve patient outcomes.

3.
J Diabetes Sci Technol ; : 19322968241231950, 2024 Mar 17.
Artigo em Inglês | MEDLINE | ID: mdl-38494876

RESUMO

BACKGROUND/OBJECTIVE: The main objective of this study is to evaluate the incremental cost-effectiveness (ICER) of the Cambridge hybrid closed-loop automated insulin delivery (AID) algorithm versus usual care for children and adolescents with type 1 diabetes (T1D). METHODS: This multicenter, binational, parallel-controlled trial randomized 133 insulin pump using participants aged 6 to 18 years to either AID (n = 65) or usual care (n = 68) for 6 months. Both within-trial and lifetime cost-effectiveness were analyzed. Analysis focused on the treatment subgroup (n = 21) who received the much more reliable CamAPS FX hardware iteration and their contemporaneous control group (n = 24). Lifetime complications and costs were simulated via an updated Sheffield T1D policy model. RESULTS: Within-trial, both groups had indistinguishable and statistically unchanged health-related quality of life, and statistically similar hypoglycemia, severe hypoglycemia, and diabetic ketoacidosis (DKA) event rates. Total health care utilization was higher in the treatment group. Both the overall treatment group and CamAPS FX subgroup exhibited improved HbA1C (-0.32%, 95% CI: -0.59 to -0.04; P = .02, and -1.05%, 95% CI: -1.43 to -0.67; P < .001, respectively). Modeling projected increased expected lifespan of 5.36 years and discounted quality-adjusted life years (QALYs) of 1.16 (U.K. tariffs) and 1.52 (U.S. tariffs) in the CamAPS FX subgroup. Estimated ICERs for the subgroup were £19 324/QALY (United Kingdom) and -$3917/QALY (United States). For subgroup patients already using continuous glucose monitors (CGM), ICERs were £10 096/QALY (United Kingdom) and -$33 616/QALY (United States). Probabilistic sensitivity analysis generated mean ICERs of £19 342/QALY (95% CI: £15 903/QALY to £22 929/QALY) (United Kingdom) and -$28 283/QALY (95% CI: -$59 607/QALY to $1858/QALY) (United States). CONCLUSIONS: For children and adolescents with T1D on insulin pump therapy, AID using the Cambridge algorithm appears cost-effective below a £20 000/QALY threshold (United Kingdom) and cost saving (United States).

5.
Diabetes Technol Ther ; 25(7): 485-491, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37229591

RESUMO

Objective: We aimed to assess whether percentage of time spent in hypoglycemia during closed-loop insulin delivery differs by age group and time of day. Methods: We retrospectively analyzed data from hybrid closed-loop studies involving young children (2-7 years), children and adolescents (8-18 years), adults (19-59 years), and older adults (≥60 years) with type 1 diabetes. Main outcome was time spent in hypoglycemia <3.9 mmol/L (<70 mg/dL). Eight weeks of data for 88 participants were analyzed. Results: Median time spent in hypoglycemia over the 24-h period was highest in children and adolescents (4.4% [interquartile range 2.4-5.0]) and very young children (4.0% [3.4-5.2]), followed by adults (2.7% [1.7-4.0]), and older adults (1.8% [1.2-2.2]); P < 0.001 for difference between age groups. Time spent in hypoglycemia during nighttime (midnight-05:59) was lower than during daytime (06:00-23:59) across all age groups. Conclusion: Time in hypoglycemia was highest in the pediatric age group during closed-loop insulin delivery. Hypoglycemia burden was lowest overnight across all age groups.


Assuntos
Diabetes Mellitus Tipo 1 , Hipoglicemia , Adolescente , Idoso , Criança , Pré-Escolar , Humanos , Glicemia , Estudos Cross-Over , Diabetes Mellitus Tipo 1/tratamento farmacológico , Hipoglicemia/induzido quimicamente , Hipoglicemia/tratamento farmacológico , Hipoglicemiantes/uso terapêutico , Insulina/efeitos adversos , Sistemas de Infusão de Insulina , Insulina Regular Humana/uso terapêutico , Estudos Retrospectivos , Resultado do Tratamento , Adulto Jovem , Adulto , Pessoa de Meia-Idade
7.
Diabetes Technol Ther ; 25(6): 431-436, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36880866

RESUMO

We evaluated the use of hybrid closed-loop (HCL) insulin delivery with faster insulin aspart (Fiasp) in very young children with type 1 diabetes (T1D). In a double-blind, multicenter, randomized, crossover study, children aged 2-6 years with T1D underwent two 8-week periods of HCL using CamAPS FX with Fiasp and standard insulin aspart (IAsp), in random order. Primary endpoint was between-treatment difference in time in target range 3.9-10.0 mmol/L. We randomized 25 participants: mean (±standard deviation) age 5.1 ± 1.3 years, baseline HbA1c 55 ± 9 mmol/mol. Time in range was not significantly different between interventions (64% ± 9% vs. 65% ± 9% for HCL with Fiasp vs. IAsp; mean difference -0.33% [95% confidence interval: -2.13 to 1.47; P = 0.71]). There was no significant difference in time with glucose <3.9 mmol/L. No post-randomization severe hypoglycemia or diabetic ketoacidosis events occurred. Use of Fiasp with CamAPS FX HCL demonstrated no significant difference in glycemic outcomes compared with IAsp in very young children with T1D. Clinical trials registration: NCT04759144.


Assuntos
Diabetes Mellitus Tipo 1 , Humanos , Criança , Pré-Escolar , Diabetes Mellitus Tipo 1/tratamento farmacológico , Insulina Aspart/uso terapêutico , Hipoglicemiantes/uso terapêutico , Estudos Cross-Over , Glicemia , Insulina/uso terapêutico , Método Duplo-Cego
8.
J Diabetes Sci Technol ; : 19322968221141924, 2022 Dec 08.
Artigo em Inglês | MEDLINE | ID: mdl-36475908

RESUMO

OBJECTIVE: Many hybrid closed-loop (HCL) systems struggle to manage unusually high glucose levels as experienced with intercurrent illness or pre-menstrually. Manual correction boluses may be needed, increasing hypoglycemia risk with overcorrection. The Cambridge HCL system includes a user-initiated algorithm intensification mode ("Boost"), activation of which increases automated insulin delivery by approximately 35%, while remaining glucose-responsive. In this analysis, we assessed the safety of "Boost" mode. METHODS: We retrospectively analyzed data from closed-loop studies involving young children (1-7 years, n = 24), children and adolescents (10-17 years, n = 19), adults (≥24 years, n = 13), and older adults (≥60 years, n = 20) with type 1 diabetes. Outcomes were calculated per participant for days with ≥30 minutes of "Boost" use versus days with no "Boost" use. Participants with <10 "Boost" days were excluded. The main outcome was time spent in hypoglycemia <70 and <54 mg/dL. RESULTS: Eight weeks of data for 76 participants were analyzed. There was no difference in time spent <70 and <54 mg/dL between "Boost" days and "non-Boost" days; mean difference: -0.10% (95% confidence interval [CI] -0.28 to 0.07; P = .249) time <70 mg/dL, and 0.03 (-0.04 to 0.09; P = .416) time < 54 mg/dL. Time in significant hyperglycemia >300 mg/dL was 1.39 percentage points (1.01 to 1.77; P < .001) higher on "Boost" days, with higher mean glucose and lower time in target range (P < .001). CONCLUSIONS: Use of an algorithm intensification mode in HCL therapy is safe across all age groups with type 1 diabetes. The higher time in hyperglycemia observed on "Boost" days suggests that users are more likely to use algorithm intensification on days with extreme hyperglycemic excursions.

9.
J Diabetes Sci Technol ; : 19322968221145184, 2022 Dec 20.
Artigo em Inglês | MEDLINE | ID: mdl-36540007

RESUMO

BACKGROUND: CamAPS FX is a hybrid closed-loop smartphone app used to manage type one diabetes. The closed-loop algorithm has a default target glucose of 5.8 mmol/L (104.5 mg/dL), but users can select personal glucose targets (adjustable between 4.4 mmol/L and 11.0 mmol/L [79 mg/dL and 198 mg/dL, respectively]). METHOD: In this post-hoc analysis, we evaluated the impact of personal glucose targets on glycemic control using data from participants in five randomized controlled trials. RESULTS: Personal glucose targets were widely used, with 20.3% of all days in the data set having a target outside the default target bin (5.5-6.0 mmol/L [99-108 mg/dL]). Personal glucose targets >6.5 mmol/L (117 mg/dL) were associated with significantly less time in target range (3.9-10.0 mmol/L [70-180 mg/dL]; 6.5-7.0 mmol/L [117-126 mg/dL]: mean difference = -3.2 percentage points [95% CI: -5.3 to -1.2; P < .001]; 7.0-7.5 mmol/L [126-135 mg/dL]: -10.8 percentage points [95% CI: -14.1 to -7.6; P < .001]). Personal targets >6.5 mmol/L (117 mg/dL) were associated with significantly lower time (<3.9 mmol/L [<70 mg/dL]; 6.5-7.0 mmol/L [117-126 mg/dL]: -1.85 percentage points [95% CI: -2.37 to -1.34; P < .001]; 7.0-7.5 mmol/L [126-135 mg/dL]: -2.68 percentage points [95% CI: -3.49 to -1.86; P < .001]). CONCLUSIONS: Discrete study populations showed differences in glucose control when applying similar personal targets.

10.
Diabetes Care ; 2022 Sep 16.
Artigo em Inglês | MEDLINE | ID: mdl-36350787

RESUMO

OBJECTIVE: To evaluate the impact of CamAPS FX hybrid closed-loop (HCL) automated insulin delivery in very young children with type 1 diabetes (T1D) on caregivers' well-being, fear of hypoglycemia, and sleepiness. RESEARCH DESIGN AND METHODS: We conducted a multinational, open-label, randomized crossover study. Children (age 1-7 years) with T1D received treatment for two 4-month periods in random order, comparing HCL with sensor augmented pump (control). At baseline and after each treatment period, caregivers were invited to complete World Health Organization-Five Well-Being Index, Hypoglycemia Fear Survey, and Epworth Sleepiness Scale questionnaires. RESULTS: Caregivers of 74 children (mean ± SD age 5 ± 2 years and baseline HbA1c 7.3 ± 0.7%; 42% female) participated. Results revealed significantly lower scores for hypoglycemia fear (P < 0.001) and higher scores for well-being (P < 0.001) after HCL treatment. A trend toward a reduction in sleepiness score was observed (P = 0.09). CONCLUSIONS: Our results suggest better well-being and less hypoglycemia fear in caregivers of very young children with T1D on CamAPS FX HCL.

11.
N Engl J Med ; 387(10): 882-893, 2022 09 08.
Artigo em Inglês | MEDLINE | ID: mdl-36069870

RESUMO

BACKGROUND: Whether improved glucose control with hybrid closed-loop therapy can preserve C-peptide secretion as compared with standard insulin therapy in persons with new-onset type 1 diabetes is unclear. METHODS: In a multicenter, open-label, parallel-group, randomized trial, we assigned youths 10.0 to 16.9 years of age within 21 days after a diagnosis of type 1 diabetes to receive hybrid closed-loop therapy or standard insulin therapy (control) for 24 months. The primary end point was the area under the curve (AUC) for the plasma C-peptide level (after a mixed-meal tolerance test) at 12 months after diagnosis. The analysis was performed on an intention-to-treat basis. RESULTS: A total of 97 participants (mean [±SD] age, 12±2 years) underwent randomization: 51 were assigned to receive closed-loop therapy and 46 to receive control therapy. The AUC for the C-peptide level at 12 months (primary end point) did not differ significantly between the two groups (geometric mean, 0.35 pmol per milliliter [interquartile range, 0.16 to 0.49] with closed-loop therapy and 0.46 pmol per milliliter [interquartile range, 0.22 to 0.69] with control therapy; mean adjusted difference, -0.06 pmol per milliliter [95% confidence interval {CI}, -0.14 to 0.03]). There was not a substantial between-group difference in the AUC for the C-peptide level at 24 months (geometric mean, 0.18 pmol per milliliter [interquartile range, 0.06 to 0.22] with closed-loop therapy and 0.24 pmol per milliliter [interquartile range, 0.05 to 0.30] with control therapy; mean adjusted difference, -0.04 pmol per milliliter [95% CI, -0.14 to 0.06]). The arithmetic mean glycated hemoglobin level was lower in the closed-loop group than in the control group by 4 mmol per mole (0.4 percentage points; 95% CI, 0 to 8 mmol per mole [0.0 to 0.7 percentage points]) at 12 months and by 11 mmol per mole (1.0 percentage points; 95% CI, 7 to 15 mmol per mole [0.5 to 1.5 percentage points]) at 24 months. Five cases of severe hypoglycemia occurred in the closed-loop group (in 3 participants), and one occurred in the control group; one case of diabetic ketoacidosis occurred in the closed-loop group. CONCLUSIONS: In youths with new-onset type 1 diabetes, intensive glucose control for 24 months did not appear to prevent the decline in residual C-peptide secretion. (Funded by the National Institute for Health and Care Research and others; CLOuD ClinicalTrials.gov number, NCT02871089.).


Assuntos
Peptídeo C , Diabetes Mellitus Tipo 1 , Hipoglicemiantes , Insulina , Adolescente , Glicemia/análise , Peptídeo C/metabolismo , Criança , Diabetes Mellitus Tipo 1/tratamento farmacológico , Diabetes Mellitus Tipo 1/metabolismo , Humanos , Hipoglicemiantes/uso terapêutico , Insulina/uso terapêutico , Sistemas de Infusão de Insulina
12.
Horm Res Paediatr ; 95(5): 476-483, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35817008

RESUMO

INTRODUCTION: Heterozygous activating mutations in KCNJ11 cause both permanent and transient neonatal diabetes. A minority of patients also have neurological features. Early genetic diagnosis has important therapeutic implications as treatment with sulfonylurea provides good metabolic control and exerts a protective effect on neuromuscular function. CASE PRESENTATION: A term female infant with normal birth weight (2.73 kg, z-score: -1.69) was admitted to the Neonatal Unit at Addenbrookes Hospital. She had been antenatally diagnosed with KCNJ11 mutation-R201C inherited from her glibenclamide-treated mother who continued sulfonylurea treatment throughout pregnancy. A continuous glucose-monitoring system inserted at 20 h of age showed progressive rise of blood glucose concentrations, prompting treatment with glibenclamide on day 2 of life. Initial attempts to treat with an extemporaneous solution of glibenclamide (starting dose 0.2 mg/kg/day) resulted in inconsistent response and significant hypoglycaemia and hyperglycaemia. A licenced liquid formulation of glibenclamide (AMGLIDIA) at a starting dose of 0.05 mg/kg/day was used with stabilization of blood glucose profile within 24 h. Other than a mild transient elevation in transaminase, treatment was well tolerated. At most recent review (age 12 months), the patient remains well with age-appropriate neurodevelopment. Overall glucose control is reasonable with estimated HbA1c of 7.6% (59.9 mmol/mol). CONCLUSION: Early postnatal glibenclamide treatment of insulin-naive patients with KATP-dependent neonatal diabetes is safe, provides good metabolic control, and has a potential protective effect on neurological function. The formulation of the medicine needs to be carefully considered in the context of the very small doses required in this age group.


Assuntos
Diabetes Mellitus , Doenças do Recém-Nascido , Canais de Potássio Corretores do Fluxo de Internalização , Lactente , Recém-Nascido , Gravidez , Humanos , Feminino , Glibureto/uso terapêutico , Glicemia/metabolismo , Hipoglicemiantes/uso terapêutico , Canais de Potássio Corretores do Fluxo de Internalização/genética , Compostos de Sulfonilureia/uso terapêutico , Mutação , Doenças do Recém-Nascido/tratamento farmacológico , Doenças do Recém-Nascido/genética
13.
Diabetes Obes Metab ; 24(12): 2309-2318, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-35837984

RESUMO

AIM: To examine changes in the lived experience of type 1 diabetes after use of hybrid closed loop (CL), including the CamAPS FX CL system. MATERIALS AND METHODS: The primary study was conducted as an open-label, single-period, randomized, parallel design contrasting CL versus insulin pump (with or without continuous glucose monitoring). Participants were asked to complete patient-reported outcomes before starting CL and 3 and 6 months later. Surveys assessed diabetes distress, hypoglycaemia concerns and quality of life. Qualitative focus group data were collected at the completion of the study. RESULTS: In this sample of 98 youth (age range 6-18, mean age 12.7 ± 2.8 years) and their parents, CL use was not associated with psychosocial benefits overall. However, the subgroup (n = 12) using the CamAPS FX system showed modest improvements in quality of life and parent distress, reinforced by both survey (p < .05) and focus group responses. There were no negative effects of CL use reported by study participants. CONCLUSIONS: Closed loop use via the CamAPS FX system was associated with modest improvements in aspects of the lived experience of managing type 1 diabetes in youth and their families. Further refinements of the system may optimize the user experience.


Assuntos
Diabetes Mellitus Tipo 1 , Adolescente , Humanos , Criança , Diabetes Mellitus Tipo 1/tratamento farmacológico , Automonitorização da Glicemia , Insulina/uso terapêutico , Qualidade de Vida , Hipoglicemiantes/uso terapêutico , Glicemia , Resultado do Tratamento , Sistemas de Infusão de Insulina , Pais/psicologia
14.
Clin Endocrinol (Oxf) ; 97(5): 551-561, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-35781728

RESUMO

OBJECTIVE: Congenital adrenal hyperplasia (CAH) requires exogenous steroid replacement. Treatment is commonly monitored by measuring 17-OH progesterone (17OHP) and androstenedione (D4). DESIGN: Retrospective cohort study using real-world data to evaluate 17OHP and D4 in relation to hydrocortisone (HC) dose in CAH patients treated in 14 countries. PATIENTS: Pseudonymized data from children with 21-hydroxylase deficiency (21OHD) recorded in the International CAH Registry. MEASUREMENTS: Assessments between January 2000 and October 2020 in patients prescribed HC were reviewed to summarise biomarkers 17OHP and D4 and HC dose. Longitudinal assessment of measures was carried out using linear mixed-effects models (LMEM). RESULTS: Cohort of 345 patients, 52.2% female, median age 4.3 years (interquartile range: 3.1-9.2) were taking a median 11.3 mg/m2 /day (8.6-14.4) of HC. Median 17OHP was 35.7 nmol/l (3.0-104.0). Median D4 under 12 years was 0 nmol/L (0-2.0) and above 12 years was 10.5 nmol/L (3.9-21.0). There were significant differences in biomarker values between centres (p < 0.05). Correlation between D4 and 17OHP was good in multiple regression with age (p < 0.001, R2 = 0.29). In longitudinal assessment, 17OHP levels did not change with age, whereas D4 levels increased with age (p < 0.001, R2 = 0.08). Neither biomarker varied directly with dose or weight (p > 0.05). Multivariate LMEM showed HC dose decreasing by 1.0 mg/m2 /day for every 1 point increase in weight standard deviation score. DISCUSSION: Registry data show large variability in 17OHP and D4 between centres. 17OHP correlates with D4 well when accounting for age. Prescribed HC dose per body surface area decreased with weight gain.


Assuntos
Hiperplasia Suprarrenal Congênita , 17-alfa-Hidroxiprogesterona , Hiperplasia Suprarrenal Congênita/tratamento farmacológico , Androstenodiona , Criança , Pré-Escolar , Feminino , Humanos , Hidrocortisona/uso terapêutico , Masculino , Progesterona , Sistema de Registros , Estudos Retrospectivos
15.
J Clin Endocrinol Metab ; 107(8): 2286-2295, 2022 07 14.
Artigo em Inglês | MEDLINE | ID: mdl-35521800

RESUMO

CONTEXT: Growth hormone (GH) is used to treat short children born small for gestational age (SGA); however, the effects of treatment on pubertal timing and adult height are rarely studied. OBJECTIVE: To evaluate adult height and peak height velocity in short GH-treated SGA children. METHODS: Prospective longitudinal multicenter study. Participants were short children born SGA treated with GH therapy (n = 102). Adult height was reported in 47 children. A reference cohort of Danish children was used. Main outcome measures were adult height, peak height velocity, age at peak height, and pubertal onset. Pubertal onset was converted to SD score (SDS) using Danish reference data. RESULTS: Gain in height SDS from start of treatment until adult height was significant in both girls (0.94 [0.75; 1.53] SDS, P = .02) and boys (1.57 [1.13; 2.15] SDS, P < .001). No difference in adult height between GH dosage groups was observed. Peak height velocity was lower than a reference cohort for girls (6.5 [5.9; 7.6] cm/year vs 7.9 [7.4; 8.5] cm/year, P < .001) and boys (9.5 [8.4; 10.7] cm/year vs 10.1 [9.7; 10.7] cm/year, P = .002), but no difference in age at peak height velocity was seen. Puberty onset was earlier in SGA boys than a reference cohort (1.06 [-0.03; 1.96] SDS vs 0 SDS, P = .002) but not in girls (0.38 [-0.19; 1.05] SDS vs 0 SDS, P = .18). CONCLUSION: GH treatment improved adult height. Peak height velocity was reduced, but age at peak height velocity did not differ compared with the reference cohort. SGA boys had an earlier pubertal onset compared with the reference cohort.


Assuntos
Estatura , Transtornos do Crescimento , Hormônio do Crescimento Humano , Recém-Nascido Pequeno para a Idade Gestacional , Puberdade , Adulto , Estatura/efeitos dos fármacos , Estatura/fisiologia , Criança , Feminino , Idade Gestacional , Transtornos do Crescimento/tratamento farmacológico , Hormônio do Crescimento Humano/farmacologia , Hormônio do Crescimento Humano/uso terapêutico , Humanos , Recém-Nascido , Recém-Nascido Pequeno para a Idade Gestacional/crescimento & desenvolvimento , Masculino , Estudos Prospectivos , Puberdade/efeitos dos fármacos , Puberdade/fisiologia , Fatores de Tempo
16.
Front Toxicol ; 4: 884704, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35499038

RESUMO

Paracetamol (acetaminophen) is the preferred antipyretic/analgesic for pregnant women as it is believed there are no adverse fetal effects at the recommended dose. However, emerging evidence suggests that intrauterine paracetamol exposure may be associated with certain urogenital/reproductive disorders in the offspring. In this mini-review, we describe human fetal sex development and possible pharmacological mechanisms by which paracetamol may disrupt this process, including reduced testicular production of testosterone and/or insulin-like peptide 3. We then review the available epidemiological literature on associations between maternal paracetamol exposure and offspring sexual development. Three epidemiological studies have reported associations between maternal paracetamol intake and increased risk of cryptorchidism, although five others have not. None have found associations with hypospadias or penile length. Two out of three studies have reported a shorter anogenital distance (a marker of androgen action during the masculinisation programming window, ∼8-14 weeks of gestation) in male infants antenatally exposed to paracetamol. One study has described a dose-dependent relationship between maternal paracetamol consumption and earlier female (but not male) attainment of puberty. Such epidemiological analyses are complicated by various factors, including method of paracetamol exposure assessment (usually retrospective self-report), variation in diagnostic accuracy, selection bias, confounding by clinical indication, and demographic/genetic differences between geographically separated populations. There is an urgent need for stronger evidence in this area, from both relevant experimental studies and large, carefully-designed prospective studies. In the meantime, a precautionary attitude to gestational paracetamol usage should be considered as the evidence for clinically significant reproductive effects in humans is limited.

17.
Pediatr Diabetes ; 23(6): 799-808, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35561092

RESUMO

OBJECTIVES: We explored parents' views about healthcare professionals having remote access to their young child's insulin and glucose data during a clinical trial to inform use of data sharing in routine pediatric diabetes care. RESEARCH DESIGN AND METHODS: Interviews with 33 parents of 30 children (aged 1-7 years) with type 1 diabetes participating in a randomized trial (KidsAP02) comparing hybrid closed-loop system use with sensor-augmented pump therapy. Data were analyzed using a qualitative descriptive approach. RESULTS: Parents reported multiple benefits to healthcare professionals being able to remotely access their child's glucose and insulin data during the trial, despite some initial concerns regarding the insights offered into everyday family life. Key benefits included: less work uploading/sharing data; improved consultations; and, better clinical input and support from healthcare professionals between consultations. Parents noted how healthcare professionals' real-time data access facilitated remote delivery of consultations during the COVID-19 pandemic, and how these were more suitable for young children than face-to-face appointments. Parents endorsed use of real-time data sharing in routine clinical care, subject to caveats regarding data access, security, and privacy. They also proposed that, if data sharing were used, consultations for closed-loop system users in routine clinical care could be replaced with needs-driven, ad-hoc contact. CONCLUSIONS: Real-time data sharing can offer clinical, logistical, and quality-of-life benefits and enhance opportunities for remote consultations, which may be more appropriate for young children. Wider rollout would require consideration of ethical and cybersecurity issues and, given the heightened intrusion on families' privacy, a non-judgmental, collaborative approach by healthcare professionals.


Assuntos
Diabetes Mellitus Tipo 1 , Pais , COVID-19 , Criança , Pré-Escolar , Atenção à Saúde , Diabetes Mellitus Tipo 1/tratamento farmacológico , Glucose , Humanos , Lactente , Insulina/uso terapêutico , Pandemias , Pais/psicologia , Pesquisa Qualitativa , Ensaios Clínicos Controlados Aleatórios como Assunto
18.
Diabetes Res Clin Pract ; 187: 109877, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35469973

RESUMO

AIMS: To explore parents' experiences of using a hybrid closed-loop system (CamAPS FX) when caring for a very young child (aged 1-7 years) with type 1 diabetes. METHODS: Interviews with n = 33 parents of 30 children who used the system during a randomised controlled trial. Data analysis used a descriptive thematic approach. RESULTS: While some parents were initially reticent about handing control to the system, all reported clinical benefits to using the technology, having to do less diabetes-related work and needing less clinical input over time. Parents welcomed opportunities to enhance the system's efficacy (using Ease-off and Boost functions) as required. Parents described how the system's automated glucose control facilitated more normality, including sleeping better, worrying less about their child, and feeling more confident and able to outsource care. Parents also described more normality for the child (alongside better sleep, mood and concentration, and lessened distress) and siblings. Parents liked being able to administer insulin using a smartphone, but suggested refinements to device size and functionality. CONCLUSIONS: Using a hybrid closed-loop system in very young children can facilitate greater normality and may result in a lessened demand for health professionals' input. Systems may need to be customised for very young children.


Assuntos
Diabetes Mellitus Tipo 1 , Glicemia/análise , Criança , Pré-Escolar , Diabetes Mellitus Tipo 1/tratamento farmacológico , Humanos , Hipoglicemiantes/uso terapêutico , Insulina/uso terapêutico , Sistemas de Infusão de Insulina , Pais , Pesquisa Qualitativa
19.
Genet Med ; 24(6): 1261-1273, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35341651

RESUMO

PURPOSE: This study aimed to undertake a multidisciplinary characterization of the phenotype associated with SOX11 variants. METHODS: Individuals with protein altering variants in SOX11 were identified through exome and genome sequencing and international data sharing. Deep clinical phenotyping was undertaken by referring clinicians. Blood DNA methylation was assessed using Infinium MethylationEPIC array. The expression pattern of SOX11 in developing human brain was defined using RNAscope. RESULTS: We reported 38 new patients with SOX11 variants. Idiopathic hypogonadotropic hypogonadism was confirmed as a feature of SOX11 syndrome. A distinctive pattern of blood DNA methylation was identified in SOX11 syndrome, separating SOX11 syndrome from other BAFopathies. CONCLUSION: SOX11 syndrome is a distinct clinical entity with characteristic clinical features and episignature differentiating it from BAFopathies.


Assuntos
Metilação de DNA , Hipogonadismo , Síndrome de Klinefelter , Transtornos do Neurodesenvolvimento , Fatores de Transcrição SOXC , Metilação de DNA/genética , Humanos , Hipogonadismo/genética , Síndrome de Klinefelter/genética , Transtornos do Neurodesenvolvimento/genética , Fenótipo , Fatores de Transcrição SOXC/genética , Sequenciamento do Exoma
20.
Lancet Digit Health ; 4(4): e245-e255, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-35272971

RESUMO

BACKGROUND: Closed-loop insulin delivery systems have the potential to address suboptimal glucose control in children and adolescents with type 1 diabetes. We compared safety and efficacy of the Cambridge hybrid closed-loop algorithm with usual care over 6 months in this population. METHODS: In a multicentre, multinational, parallel randomised controlled trial, participants aged 6-18 years using insulin pump therapy were recruited at seven UK and five US paediatric diabetes centres. Key inclusion criteria were diagnosis of type 1 diabetes for at least 12 months, insulin pump therapy for at least 3 months, and screening HbA1c levels between 53 and 86 mmol/mol (7·0-10·0%). Using block randomisation and central randomisation software, we randomly assigned participants to either closed-loop insulin delivery (closed-loop group) or to usual care with insulin pump therapy (control group) for 6 months. Randomisation was stratified at each centre by local baseline HbA1c. The Cambridge closed-loop algorithm running on a smartphone was used with either (1) a modified Medtronic 640G pump, Medtronic Guardian 3 sensor, and Medtronic prototype phone enclosure (FlorenceM configuration), or (2) a Sooil Dana RS pump and Dexcom G6 sensor (CamAPS FX configuration). The primary endpoint was change in HbA1c at 6 months combining data from both configurations. The primary analysis was done in all randomised patients (intention to treat). Trial registration ClinicalTrials.gov, NCT02925299. FINDINGS: Of 147 people initially screened, 133 participants (mean age 13·0 years [SD 2·8]; 57% female, 43% male) were randomly assigned to either the closed-loop group (n=65) or the control group (n=68). Mean baseline HbA1c was 8·2% (SD 0·7) in the closed-loop group and 8·3% (0·7) in the control group. At 6 months, HbA1c was lower in the closed-loop group than in the control group (between-group difference -3·5 mmol/mol (95% CI -6·5 to -0·5 [-0·32 percentage points, -0·59 to -0·04]; p=0·023). Closed-loop usage was low with FlorenceM due to failing phone enclosures (median 40% [IQR 26-53]), but consistently high with CamAPS FX (93% [88-96]), impacting efficacy. A total of 155 adverse events occurred after randomisation (67 in the closed-loop group, 88 in the control group), including seven severe hypoglycaemia events (four in the closed-loop group, three in the control group), two diabetic ketoacidosis events (both in the closed-loop group), and two non-treatment-related serious adverse events. There were 23 reportable hyperglycaemia events (11 in the closed-loop group, 12 in the control group), which did not meet criteria for diabetic ketoacidosis. INTERPRETATION: The Cambridge hybrid closed-loop algorithm had an acceptable safety profile, and improved glycaemic control in children and adolescents with type 1 diabetes. To ensure optimal efficacy of the closed-loop system, usage needs to be consistently high, as demonstrated with CamAPS FX. FUNDING: National Institute of Diabetes and Digestive and Kidney Diseases.


Assuntos
Diabetes Mellitus Tipo 1 , Cetoacidose Diabética , Adolescente , Algoritmos , Glicemia/análise , Criança , Diabetes Mellitus Tipo 1/tratamento farmacológico , Cetoacidose Diabética/induzido quimicamente , Feminino , Humanos , Hipoglicemiantes/uso terapêutico , Insulina/uso terapêutico , Sistemas de Infusão de Insulina , Masculino
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...